Defibrillator
Defibrillator
AED Defibrillator

Portable AED defibrillator with NIBP,Spo2,Co2 and pacer

Display: 7inch TFT

Standard parameter:AED,Bipasic,ECG,printer

Operation mode: AED mode and manual mode

Application: AMBLUENCE,first-aid,ICU

JQ-Xpress Portable AED type Bipasic defibrillator with NIBP,Spo2,Co2 and pacer function optional 

5 Languages available: English.Russian.Spanish.Chinese.Turkish

 

Technical specifications:

JQ-Xpress defibrillator integrated monitoring, manual defibrillation, AED and pacer (option). It is a professional biphasic defibrillator monitor ,suitable for hospitals and clinics.

Display

Screen Type: High-resolution display

Screen Size: 7 inches (17.7 cm) diagonally

Sweep Speed: 25mm/sec

Information: Heart Rate .  Lead/Pads.  Alarm .  On/Off  . SpO2 .  AED

Functions and Prompts Alarm Selection and Limits Delivered Energy.

5 Languages available: English.Russian.Spanesh.Chinese.Turkish
Defibrillator

Waveform: Biphasic

Charge Time: Less than 7 seconds with a new fully charged battery.

Energy Display: Monitor display indicates both selected and delivered energy.

Charge Prompt Type: Voice and visual prompts.

Electrode Impedance Measurement Range: 0-250 ohms.

ECG Monitoring

Patient Connection: 3-lead ECG cable or 5-lead ECG cable paddles.

Lead Selection: Displayed on monitor paddles I II III AVR AVL AVF V.

ECG Size: 0.25 0.5 1 1.5 2 4 cm/mV display on monitor.

Heart Rate: 20-300BPM.

Heart Rate Alarm: On/Off displayed on monitor user-selectable.

Smart Alarms: Beeper/voice prompts indicate shock able rhythm.

High-resolution thermal Printer. 
Printing method: High resolution,thermal print head

Print-out mode:Manual or automatic or user-configurable
Paper Width: 50 mm.
Paper Speed: 12.5mm/sec,25 mm/sec, 50 mm/sec
User selectable 6 seconds delay

AED Mode

AED function:Auto analyze and charge X3 with programmable auto energy level selection,screen prompts,and voice prompts

Shockable Rhythms:Ventricular fibrillation with amplitude≥ 200uV,ventricular tachycardia with rates ≥ 140bpm,and QRS complex wave duration ≥ 140ms.

Charge Control:control on device front panel,press key on paddle

Prompts: Voice and visual prompts

Manual Mode

Engery Selection:Selectable at 2,5,7,10,20,30,50,70,100,150,200,300,360 joules.

Synchronized Mode:Synchronizes defibrillator pulse to patient’s

R-wave.”SYNC” message displayed on monitor

Battery

Type: Rechargeable Ni-MH battery 12V.

Operating Time: For a new fully charged battery: 60 defibrillator discharges at maximum energy or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating    time with different functions.

SpO2 Module (Optional need extra cost):

Measurement Range: 30~100% ±2% between 80%~90% others ±5%

Alarm Range: User set high limit and low limit.

Alarm Accuracy: ±10% within setting values.

Alarm time Accuracy: less than 12 sec.

1-Meditech Pulse Oximeter

2-Nellcor Pulse Oximeter

Product Enquiry

Contact us